图 1 


Product name: 3.5 KW electromagnetic heating control panel

3.5 KW

3.5 KW electromagnetic heating panel specification

A, technical parameters

1: the dimensions: 207 * 138 * 115 (length * width * height)

2: working voltage: 220 v

(adjustable) : 3: power 2500 w to 3500 w

4: the load inductance: 120 + 10 uh (measured with victor BICTOR6243 + inductance table)

5: conversion efficiency > 90%

6: working frequency: 20 to 25 KHZ

7: working temperature: - 10 degrees to + 50 degrees

8: works: continuous heating

9: the wave impact protection - + 1500 v

10: clutter interference: 4000 v

11: induction coil to the installation of heating element from 15 mm (after heat preservation cotton compaction thickness)

Second, the wiring instructions

1, the three lights, for power supply lamp ", "" work light" and "trouble light lamp. Normal work power lamp ", "" work light" in the light. The trouble light lights went out. When power failure occurs when the trouble light lamp in shine.

2, power 220 v on the pillars of the "220 v alternating current (ac)", regardless of firewire zero random access.

3, the coil in the electromagnetic coil two ends "of the two terminal, tighten the screws.

4, electromagnetic heating panel factory set for the power supply can work, "controlled" switch socket mouth at this time there is a short route (black) to the outlet short circuit. Also can use handle gently on the next "switch control", the only outlet short route (black), will be one of the two core online line one end into the socket switch control, the other end of the two plugs from the thermostat two normally open contacts, linked to commissioning.


Previous:2 kw induction heater